FiberOLT Team | Quick Response | Fast Delivery
Sales@fiberolt.com
Fiberolt
Login / Register
Sign inCreate an Account

Lost your password?

0 items $0.00
Menu
Fiberolt
0 items $0.00
Browse Categories
  • Optical SFP Transceiver
    • Huawei
      • 100G QSFP28 Module
      • 10G SFP+ Module
      • 25G SFP28 Module
      • 40G QSFP Module
      • GE SFP Module
    • Cisco
      • 100G QSFP28 Module
      • 25G SFP28 Module
      • 400G Module
      • 40G QSFP Module
      • GBIC Module
      • SFP GLC Module
    • Custom
      • 100G QSFP28 Module
      • 10GE SFP+ Module
      • 25G SFP28 Module
      • 400GE Module
      • 40G QSFP Module
      • GE Module
    • High Speed Cables
      • Active Optical Cables
      • Direct Attached Cables
  • Optical Access Network
    • Huawei OLT
      • Huawei MA5600T Board
      • Huawei MA5600T Chassis
      • Huawei MA5800 Board
      • Huawei MA5800 Chassis
      • Huawei PON Module
    • ZTE OLT
      • ZTE ZXA10 C300 Board
      • ZTE ZXA10 C300 Chassis
      • ZTE ZXA10 C600 Board
      • ZTE ZXA10 C600 Chassis
    • Nokia & Fiberhome OLT
      • Fiberhome AN5516 Series
      • Fiberhome AN6000 Series
      • Nokia 7360 ISAM Series
    • Power Facility
      • Embedded Subrack
      • Rectifier Module
      • SMU Module
  • Passive Components
    • PLC Splitter
      • ABS BOX Splitter
      • Bare Fiber Splitter
      • Blockless Splitter
      • Cassette Splitter
    • Fiber Connector
      • Fast Connector
      • Fiber Adapter
      • Fiber Attenuator
    • Fiber Cable
      • Fiber Patch Cord
      • Fiber Pigtail
  • Fiber Chassis
    • Media Converter
      • FE Media Converter
      • GE Media Converter
      • 10G Media Converter
    • Optic Termination
      • Fiber Optic Terminal Box
      • Optical Distribution Frame
  • FTTx Tester & Tool
    • FIBER TESTER
      • OTDR
      • Optical Power Meter
    • Installation Tools
      • Fiber Fusion Splicers
      • Fiber Optic Tool Kits
  • Switches
    • HUAWEI SWITCH
      • S6730 Series HOT
      • S6720 Series
      • S5730 Series HOT
      • S5720 Series
      • S1700/S2700/S3700 Series
      • CE8800 Series
      • CE6800 Series
      • CE5800 Series
    • CISCO SWITCH
      • Catalyst 9600
      • Catalyst 9500 HOT
      • Catalyst 9400
      • Catalyst 9300
      • Catalyst 9200
      • Catalyst 1300
      • Catalyst 1200
      • Catalyst 1000
    • JUNIPER SWITCH
      • QFX5130 / QFX5120 / QFX5110
      • EX4650 / EX4600
      • EX4400 / EX4300 / EX4100
      • EX3400 / EX2300
      • QFX5220 / QFX5210 / QFX5200
    • H3C SWITCH
      • S6500 Series
      • S5500 Series
      • S5100 Series
      • S5000 Series
      • S3600 Series
      • S1800 Series
  • Servers
    • XFUSION Servers
      • 1288H V7
      • 1158H V7
      • 1258H V7
      • 1288H V6
      • 1288H V5
      • 2258H V8
      • 2288H V8
      • 2288H V7
      • 2258H V7
      • 5885H V6
    • Spare Parts
      • Mainboard
      • CPU
      • Hard Disk
      • HBA / IB Card
      • RAID Card
      • Network Card
      • IO Module
      • Memory Module
      • Power Module
      • OCP Card
  • Home
  • Blog
  • Service
  • Contact us
Home Servers XFUSION Servers 1158H V7 FusionServer 1158H V7
FusionServer 1288H V7
FusionServer 1288H V7
Back to products
Placeholder
S5751-L24P2J-RUA
1158H V7

FusionServer 1158H V7

1158H V7 1U rack server

Quote now
Category: 1158H V7
Share:
  • Description
  • Specification
  • FAQ
  • Reviews (0)
  • Shipping & Delivery
Description

FusionServer 1158H V7 (1158H V7) is a new-generation 1U 1-socket rack server designed for the Internet, Internet Data Center (IDC), cloud computing, enterprise business, and telecom. The 1158H V7 is ideal for IT core services, virtualization, high-performance computing (HPC), and other complex workloads. The 1158H V7 features low power consumption, high scalability and reliability, easy deployment, and simplified management.

High Computing Density

-High computing density: 1 x 400 W CPUs with highest specifications and 24 x DDR5 DIMMs in a 1U space

– Fast interconnections boosting applications: PCIe 5.0 and 400 Gbit/s interconnections between NICs

– High-speed flash multiplying performance: 10 x 2.5″ SAS/SATA drives/NVMe SSDs

Solid Reliability and Security

– Heat pipe remote heat dissipation technology, ensuring reliable heat dissipation and stronger temperature
adaptation and improving the heat dissipation capability of a single heat sink by 50%

– Automatically collect fault information when the CPU crashes to support quick fault location

– RoT-based secure boo

Efficient Energy Saving

– The unique algorithm is provided for the lowest power consumption of fans and CPUs, saving energy by up to 8% compared with the industry average- Three core power supply technologies used to improve supply power and efficiency and enable the indus try

-leading power conversion rate and the power loss 12.5% lower than the industry average

– Intelligent service awareness and dynamic CPU clock speed adjustment based on actual service loads

Intelligent O&M

-Automatic version push and contactless upgrades, improving upgrade efficiency by 20 times

– 75% tool-based deployment, improving deployment efficiency by 10 times

– Takeover of all vendors’ servers, automatic asset locating, real-time tracking, and 100% accuracy of asset stocktaking

Specification

Specification

Form Factor 1U rack server
Processor 1x4thGenAMD®EPYC9004Series processors (Genoa) withupto400WTDPperprocessor
Memory 24xDDR5DIMMsslots,delivering upto4800MT/s
Local Storage Hot-swappableandflexibledriveconfigurations:
•10×2.5″SAS/SATAdrives/SSDs (up to4xNVMeSSDsor8xSAS/SATAdrives)
•10×2.5″SAS/SATA/NVMedrives/SSDs
•2 xM.2SSDs(SATA/NVMe)
RAID RAID0,1,10, 5,50,6,and60; supercapacitor forcachedataprotection against power failures; RAID
levelmigration, drive roaming, self-diagnosis, and remoteweb-based configuration
Network 2xOCP3.0NIC,whichcanbeconfiguredasrequired andsupports hot swapandPCIe5.0
PCIe Expansion 5xPCIeexpansion slots, including2xFlexIOexpansion slot dedicated foranOCP3.0NICand3x
standard PCIeslots,oneofwhichsupportsPCIe5.0
Fan Module 8xhot-swappable counter-rotating fanmodules inN+1redundancy
Power Supply 900W Platinum/Titanium hot-swappable power supply, 1500W/2000W Platinum power supply, supports
1+1 redundancy
Management The iBMCchip integratesonededicatedmanagementGE networkport, providing
comprehensive management features suchasfault diagnosis, automaticO&M,and
hardwaresecurityhardening.
•TheiBMCsupports standard interfaces suchasRedfish,SNMP,and IPMI2.0,provides aremote
management interface basedon HTML5/VNC KVM, and supports out-of-bandmanagement functions
such asmonitoring, diagnosis, configuration, Agentless, and remotecontrol forsimplifiedmanagement.
• It is optional to configure the FusionDirectormanagementsoftware thatprovidesadvanced
management featuressuch as five intelligent technologies,enablingan intelligent,automatic,
visualized,andrefined management throughout thelifecycle.
OS FusionOS,MicrosoftWindows Server,SUSE LinuxEnterpriseServer,VMwareESXi, Red Hat
Enterprise Linux, CentOS,Oracle, Ubuntu, Debian, andopenEuler
Security Power-onpassword,administratorpassword,Trusted PlatformModule (TPM) 2.0*, security panel, secure
boot, andchassiscover openingdetection
Operating Temperature 5°Cto40°C(41°Fto104°F),compliant withASHRAEClassesA1toA3
Certification CE,NRTL,CCC,FCC,VCCI,andRoHS
Installation Suite L-shaped, adjustable, andholding rails
Dimensions (H x W x D) 43.5mmx447mmx798mm(1.71in.x17.60 in.x31.42 in.)

 

FAQ

FAQ

Q: Which processors are supported by the FusionServer 1158H V7?

A: The server supports the latest Intel Xeon Scalable processors, including high-core-count CPU configurations optimized for enterprise and virtualization workloads.

Before upgrading processors, engineers should verify:

  • BIOS compatibility
  • CPU thermal design power (TDP)
  • Power supply capacity
  • Cooling requirements

Mixing different CPU models in dual-socket configurations is not recommended.

Q: Does the FusionServer 1158H V7 support DDR5 memory?

A: Yes. The server supports high-speed DDR5 memory, providing significantly improved bandwidth and energy efficiency compared to previous DDR4 platforms.

For optimal performance:

  • Populate memory channels evenly
  • Use identical DIMM specifications
  • Avoid mixing different memory frequencies

Improper memory population may reduce overall memory speed automatically.

Q: Can third-party NVMe SSDs be installed in the FusionServer 1158H V7?

A: Yes, but compatibility depends on the SSD firmware and PCIe protocol support. Some third-party drives may:

  • Trigger fan alarms
  • Fail hot-swap detection
  • Cause RAID controller compatibility issues
  • Not report health status correctly in iBMC

Enterprise-grade validated SSDs are generally recommended for production deployments.

Q: Why are the cooling fans running at very high speed?

A: High fan speed is usually triggered by:

  • Unsupported PCIe cards
  • Firmware mismatches
  • Missing air ducts or drive blanks
  • Abnormal temperature sensor readings

The server increases fan speed automatically to protect hardware stability. Updating firmware and checking hardware compatibility often resolves the issue.

Q: Is the FusionServer 1158H V7 suitable for VMware or virtualization clusters?

A: Yes. The platform is commonly deployed in:

  • VMware ESXi environments
  • Proxmox VE clusters
  • Hyper-V infrastructures
  • OpenStack private clouds

Recommended practices include:

  • Using NVMe SSDs for VM storage
  • Separating management and VM traffic
  • Balancing memory across CPUs
  • Enabling CPU virtualization features in BIOS

Q: What storage RAID levels are commonly used on this server?

A: Typical enterprise RAID configurations include:

  • RAID 1 for operating systems
  • RAID 5 for balanced storage efficiency
  • RAID 10 for high-performance virtualization
  • RAID 6 for large-capacity data protection

RAID 10 is often preferred for virtualization workloads due to its better write performance and rebuild reliability.

Q: Why does RAID rebuild performance become slow?

A: RAID rebuild speed may decrease because:

  • Production workloads are consuming disk I/O
  • RAID protection policies prioritize business traffic
  • Large-capacity drives require longer rebuild times
  • HDD arrays rebuild slower than NVMe SSD arrays

Engineers usually schedule rebuild operations during maintenance windows to reduce service impact.

Q: Does the FusionServer 1158H V7 support GPU acceleration?

A: Yes, depending on the chassis configuration and riser card layout. Before installing GPUs, verify:

  • PCIe slot availability
  • Power supply wattage
  • Cooling requirements
  • GPU physical dimensions

Some high-power GPUs may not be suitable for continuous operation in compact rack configurations.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “FusionServer 1158H V7” Cancel reply

Your email address will not be published. Required fields are marked *

40 ÷ = 4

Shipping & Delivery

Shipping Incoterms

Fiberolt.com provides the most commonly used incoterms for your shipping.

EXW – Ex Works

We make the cargo available at our factory, or your designated agency and location in China mainland city with free charges.

CIF – Cost, Insurance & Freight

You will receive the cargo in your country with insurance, which is essential for international transportation to guarantee your property security.

DDP – Delivered Duty Paid

Never worry about the custom clearance and duty fees, all charges are included, just wait for the cargo at your gate.

Shipping Ways

To ensure your merchandise arrive safely and timely with the assistance of our reliable international carriers, we have flexible shipping ways by Express, AirCargo, Marine and Road.According to your specific requirement and cargo volumes, our sales representative will offer the most suitable and cost-effective shipping method for you.

Methods

Tools

Time

Destination

DHL/FedEx/UPS/TNT

Airplane

5~7 days

Door to Door

Airway

Airplane

7~10 days

Airport

Marine

Vessel

30~45 days

Seaport

Road

Truck/Train(China-Europe Railway)

Unstable

Assigned Address

1 Year Warranty

24/7 Support

Flexible Payment

Fast Delivery

  • GET IN TOUCH
    • Email: sales@fiberolt.com
    • Phone No. / Whatsapp: +86-17713580041
  • CUSTOMER CARE
    • Shipping & Returns
    • Quality & Warranty
    • Terms & Payments
  • COMPANY
    • Blog
    • About us
    • Contact us
  • HELP CENTER
    • You are deserved to own an experienced sales manager at Fiberolt.com.


    Captcha ÷ 4 = 2

    Follow Us for More Valued Information

    Payment System:

    Shipping System:

    Our Social Links:

    Facebook Twitter Pinterest Linkedin Telegram
    Copyright© 2026 Fiberolt All Rights Reserved.
    GPON OLT, SFP Transceivers, Splitters, Connectors etc, Fiber Chassis, Switches
    • Menu
    • Categories
    • Optical SFP Transceiver
      • Huawei
      • Cisco
      • Custom
      • High Speed Cables
    • Passive Components
      • PLC Splitter
      • Fiber Cable
      • Fiber Connector
    • Optical Access Network
      • Huawei OLT
      • ZTE OLT
      • Nokia & Fiberhome OLT
      • Power Facility
    • Fiber Chassis
      • Media Converter
      • Optic Termination
    • FTTx Tester & Tool
      • Fiber Tester
      • Installation Tools
    • Switches
    • Home
    • Blog
    • Service
    • Contact us
    Shopping cart
    Close
    Home
    Shop
    Blog

    Send us an email

    Please kindly fill in the below info to submit the enquiry.